Neoceram®

DESCRIPTION
Neoceram® is a glass product that offers continuous, high temperature use (700° C / 1292° F) with no fear of destruction from high heat or temperature variation (water or snow on hot glass).

PROPERTIES
Color: TRANSPARENT
Thermal:
Thermal expansion coefficient
x 10-7/°C
-50 ~ 0°C
-8.5
0 ~ 50°C
-6.5
30 ~ 380°C
-6.0
30 ~ 750°C
-3.0
Specific heat
cal/g•°C
25°C
0.17
Thermal conductivity
Kcal/m-hr-°C
25°C
1.3
Max. service temp.
°C
Continuous
700*
Short term
800*
Thermal shock resistance**
°C
100 x 100 x 3 mm Plate
800
Optical: Index of refraction (nd)
1.541
ABBE number (νd)
57
Stress-optical coefficient mμ/cm/kg/cm2 25°C
3.0
Mechanical: Density
g/cm3
2.51
Bending Strength
kgf/cm2
JIS R-1601
1400
Vicker's Hardness
Hv (0.2)
700
Knoop Hardness
Hk (0.2)
500
Young's Modulus
x 103 kgf/cm2
0.9
Chemical:
Acid Resistance
(5% HCl)
mg/cm2
90°C
24 hrs.
0.1
Alkali Resistance
(5%Na2CO3)
mg/cm2
90°C
24 hrs.
0.3
Water Resistance ***
(H2SO4)
ml
0.19
Electrical: Volume resistivity (Log ρ)
Ω-cm
25°C
11.4
250°C
6.4
360°C
5.3
Dielectric Constant (ε)
1 MHz, 25°C
7.5
2.45 GHz, 25°C
-
Loss Tangent (tan δ)
x 10-3
1 MHz, 25°C
22
2.45 GHz, 25°C
-
Loss Factor
x 10-2
1 MHz, 25°C
167
2.45 GHz, 25°C
-

* Maximum service temperature: Determination of the maximum service temperature is based on mechanical information, and is the temperature of which 100 x 300 x 3.8τ mm plate specimens (supported to form a 280-mm span) deform by 1 mm after 1,000 hours continuous or 24 hours of short term heating.
** These figures are only general values derived by a procedure consisting of heated specimens which are then rapidly cooled by plunging them into water. Thermal shock properties of 100°C signify that specimens have been heated to 110°C and plunged into water at 10°C without exhibiting cracking.
*** 10g of specimen (grain size: 300 to 425 microns) is immersed in 50cc of water in an autoclave of 121°C for 30 minutes, then the test solution is titrated by 0.02N H2SO4 (ASTM).